Proceedings of the International Conference on Electronics, Mechanics, Culture and Medicine

Analysis of Turbidity Measurement Based on Ratio Method

Authors
Nan Xie, Weimin Chen, Zhennan Zhang, Yijia Yuan
Corresponding Author
Nan Xie
Available Online February 2016.
DOI
10.2991/emcm-15.2016.77How to use a DOI?
Keywords
Turbidity measurement; Ratio method; Signal processing; Circuit design
Abstract

Fine suspended matter such as sediment, organic matter and inorganic matter can absorb a large amount of bacteria, viruses and other harmful substances, which is a threat to human health, and water turbidity is one of the important indicators of water quality monitoring. The ratio method of the photoelectric detection about turbidity measurement has been applied, and the corresponding hardware circuit design and software design of the turbidity measurement system also have been done. The water turbidity measurement system can complete data acquisition and data analysis, and compare with the relation curves between the data measured by the system’s turbidity sensor and the actual turbidity value, and the least square method is used for modeling analysis and data compensation. The experimental results show that the ratio method is more accurate than the transmission method and scattering method to measure the turbidity of water samples, and the method has better interference rejection. The system design can be used in different water turbidity measurement or correction, and it has good market application prospect.

Copyright
© 2016, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the International Conference on Electronics, Mechanics, Culture and Medicine
Series
Advances in Computer Science Research
Publication Date
February 2016
ISBN
10.2991/emcm-15.2016.77
ISSN
2352-538X
DOI
10.2991/emcm-15.2016.77How to use a DOI?
Copyright
© 2016, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Nan Xie
AU  - Weimin Chen
AU  - Zhennan Zhang
AU  - Yijia Yuan
PY  - 2016/02
DA  - 2016/02
TI  - Analysis of Turbidity Measurement Based on Ratio Method
BT  - Proceedings of the International Conference on Electronics, Mechanics, Culture and Medicine
PB  - Atlantis Press
SP  - 412
EP  - 416
SN  - 2352-538X
UR  - https://doi.org/10.2991/emcm-15.2016.77
DO  - 10.2991/emcm-15.2016.77
ID  - Xie2016/02
ER  -