Data Communication of Process Control System for Plate Mill
- DOI
- 10.2991/icmia-16.2016.93How to use a DOI?
- Keywords
- Plate mill, Process control system, Data communication
- Abstract
For plate mill, data communication between Process Control System (PCS) and other system are built with different communication methods. The communication between PCS and Basic Automation system (BAS) is based on the industry Ethernet. Every 200ms, BAS sends actual data to PCS, and PCS sends setup data to BAS according to the trigger events. The communication between PCS and Human Machine Interface (HMI) is based on OPC protocol, and data tags are used. Mediation tables are used for the database communication between PCS and Manufacturing Execution System (MES). Socket method is used for the plate mill PCS to communicate with furnace PCS, control cooling PCS and gauge meter system. All these communication methods have been used for the plate mill PCS on site.
- Copyright
- © 2016, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Zhijie Jiao AU - Xiaotong Meng AU - Chunyu He AU - Jun Wang PY - 2016/11 DA - 2016/11 TI - Data Communication of Process Control System for Plate Mill BT - Proceedings of the 2016 5th International Conference on Measurement, Instrumentation and Automation (ICMIA 2016) PB - Atlantis Press SN - 1951-6851 UR - https://doi.org/10.2991/icmia-16.2016.93 DO - 10.2991/icmia-16.2016.93 ID - Jiao2016/11 ER -