Proceedings of the 2nd International Symposium on Computer, Communication, Control and Automation (ISCCCA 2013)

Multi-parameters Measurement Based on STM32 ARM of Dual-excited Electromagnetic Flow Meter in Partially Filled Pipes

Authors
Ji Suo, Chunqing Qi, Hongbing Zhang
Corresponding Author
Ji Suo
Available Online February 2013.
DOI
10.2991/isccca.2013.187How to use a DOI?
Keywords
Arc-electrode, liquid level, flow velocity, STM32, sensitivity
Abstract

The dual-excited electromagnetic flowmeter with arc-electrodes in the paper can measures liquid level and flow velocity. A pair of electrodes is set as signal injection electrodes on the pipe bottom. AC signal injected used to determine liquid level. The theoretical analysis and experiment results indicate that it is feasible for partially filled pipes.

Copyright
© 2013, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the 2nd International Symposium on Computer, Communication, Control and Automation (ISCCCA 2013)
Series
Advances in Intelligent Systems Research
Publication Date
February 2013
ISBN
10.2991/isccca.2013.187
ISSN
1951-6851
DOI
10.2991/isccca.2013.187How to use a DOI?
Copyright
© 2013, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Ji Suo
AU  - Chunqing Qi
AU  - Hongbing Zhang
PY  - 2013/02
DA  - 2013/02
TI  - Multi-parameters Measurement Based on STM32 ARM of Dual-excited Electromagnetic Flow Meter in Partially Filled Pipes
BT  - Proceedings of the 2nd International Symposium on Computer, Communication, Control and Automation (ISCCCA 2013)
PB  - Atlantis Press
SP  - 745
EP  - 748
SN  - 1951-6851
UR  - https://doi.org/10.2991/isccca.2013.187
DO  - 10.2991/isccca.2013.187
ID  - Suo2013/02
ER  -