Proceedings of the 2nd Syedza Saintika International Conference on Nursing, Midwifery, Medical Laboratory Technology, Public Health, and Health Information Management (SeSICNiMPH 2021)

Comparasion Between Pooled Sera Material and Commercial Serum on the Accuracy of Triglyceride Check

Authors
Wiwit Nia Anggra, Ibrahim, Rahmi Novita Yusuf
Corresponding Author
Rahmi Novita Yusuf
Available Online 28 October 2021.
DOI
10.2991/ahsr.k.211026.066How to use a DOI?
Keywords
triglyceride, pooled sera, commercial serum
Abstract

The increase in cases of dyslipidemia every year, requires the Clinical Chemistry laboratory to carry out quality control which is influenced by the assessment of precision and accuracy. These measurements are used with the control material. The laboratory of RSU Mayjen HA Thalib Kerinci uses commercial serum control materials as control materials that are used daily in the triglycerides check, and has never used pooled sera. In fact, there are several advantages to using pooled sera as a control material. The reseach is an analytic survey research with a comparative study method. The sampling technique used was purposive sampling. Data collected by using an observation sheet. Data were processed in computerized with univariate analysis and bivariate analysis using independent t-test. The results showed that the average value of the triglyceride check by using Pooled Sera control material was 94.67 mg / dL with a standard deviation of 2.52, the coefficient of variance was 2.66%. While the test results of triglycerides with Commercial Serum control material was 79.13 mg / dL with a Standard Deviation of 3.57, the coefficient of variance is 4.51%. It was concluded that there was a significant difference between the triglyceride check with Pooled Sera and Commercial Serum materials. It is recommended that the development of medical laboratory technology in hospitals, making this research to be a reference in educational institutions, and for further research on other parameters, including Pooled Sera and other Serum materials.

Copyright
© 2021, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the 2nd Syedza Saintika International Conference on Nursing, Midwifery, Medical Laboratory Technology, Public Health, and Health Information Management (SeSICNiMPH 2021)
Series
Advances in Health Sciences Research
Publication Date
28 October 2021
ISBN
10.2991/ahsr.k.211026.066
ISSN
2468-5739
DOI
10.2991/ahsr.k.211026.066How to use a DOI?
Copyright
© 2021, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Wiwit Nia Anggra
AU  - Ibrahim
AU  - Rahmi Novita Yusuf
PY  - 2021
DA  - 2021/10/28
TI  - Comparasion Between Pooled Sera Material and Commercial Serum on the Accuracy of Triglyceride Check
BT  - Proceedings of the 2nd Syedza Saintika International Conference on Nursing, Midwifery, Medical Laboratory Technology, Public Health, and Health Information Management (SeSICNiMPH 2021)
PB  - Atlantis Press
SP  - 330
EP  - 334
SN  - 2468-5739
UR  - https://doi.org/10.2991/ahsr.k.211026.066
DO  - 10.2991/ahsr.k.211026.066
ID  - Anggra2021
ER  -