Number Simulation and Optimization of Air Distribution in a Data Room

Authors
Huifen Zou, Yu Rong
Corresponding Author
Huifen Zou
Available Online September 2012.
DOI
10.2991/emeit.2012.79How to use a DOI?
Keywords
Data center, Computational fluid dynamics, Air distribution
Abstract

With the rapid development of communication industry, many kinds of severs are displayed in the data center today. Their different power consumptions lead to different heat diffusion. The decorate position of air conditioning units have sever effects on the air distribution and the operation of all kinds of facilities [1, 2]. As a background of this kind of area, three different positions of air conditioning units had been used to analyze how they affected the data center’s thermal environment by means of combining field measurements with computational fluid dynamics. Thus we got a suitable decorate position which can provide better air distribution. Based on these, this work made a further analysis of two kinds of air conditioning modes of bottom income and top outcome. The scheme had been optimized again and the server performance had also been improved. This work had presented proof for the design of air distribution and the retrofit of existing data center.

Copyright
© 2012, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the 2nd International Conference on Electronic & Mechanical Engineering and Information Technology (EMEIT 2012)
Series
Advances in Intelligent Systems Research
Publication Date
September 2012
ISBN
978-90-78677-60-4
ISSN
1951-6851
DOI
10.2991/emeit.2012.79How to use a DOI?
Copyright
© 2012, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Huifen Zou
AU  - Yu Rong
PY  - 2012/09
DA  - 2012/09
TI  - Number Simulation and Optimization of Air Distribution in a Data Room
BT  - Proceedings of the 2nd International Conference on Electronic & Mechanical Engineering and Information Technology (EMEIT 2012)
PB  - Atlantis Press
SP  - 396
EP  - 399
SN  - 1951-6851
UR  - https://doi.org/10.2991/emeit.2012.79
DO  - 10.2991/emeit.2012.79
ID  - Zou2012/09
ER  -