Proceedings of the 2021 10th International Conference on Applied Science, Engineering and Technology (ICASET 2021)

Parameters Calibration of CT System Based On Geometric Model and Inverse Radon Transform

Authors
Huang Hongliang, Tang Weiyu, Yang Juntao, Wang Lidong
Corresponding Author
Wang Lidong
Available Online 18 August 2021.
DOI
10.2991/aer.k.210817.026How to use a DOI?
Keywords
Parameter calibration, Inverse Radon transform, Inverse filtering algorithm, Image reconstruction
Abstract

CT technology can make use of the penetrability of X-ray to obtain the internal information of the object without damaging the shape and structure of the sample. Therefore, it has a wide range of applications in the fields of industry, non-destructive testing and medical imaging. However, in the installation process of CT system, there are often some problems, such as inaccurate detector spacing, rotation angle and rotation center deviation, resulting in unclear image reconstruction. Thus it is necessary to calibrate the parameters of the installed system with template data, and then image the unknown samples in the process of CT system installation. This paper studies the parameter calibration of CT system. Through the pre-processed data, the analytic geometry model and statistical analysis method are established to calculate the detector interval, 180 rotation angles and rotation center of CT system. In order to verify the accuracy and stability of the parameters, Non-Local Means denoising algorithm (shortly known as NLM denoising algorithm) and Radon inverse transform imaging theorem are introduced. The theoretical image is rebuilt by the absorptivity of the template. The error between the theoretical image and the geometric information of the original template is analyzed, and the fitting is excellent. Two new inhomogeneous media are introduced, and the image is imaged by the parameters obtained from the parameter calibration model and the imaging theorem in this paper. The results are clear and the shadow points are excluded. At the same time, the specific absorptivity of the media is obtained. The calibration model of CT system parameters obtained in this paper, combined with imaging algorithm, can deal with different shapes and irregular conditions. It has great application value in the field of image reconstruction and medicine.

Copyright
© 2021, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the 2021 10th International Conference on Applied Science, Engineering and Technology (ICASET 2021)
Series
Advances in Engineering Research
Publication Date
18 August 2021
ISBN
10.2991/aer.k.210817.026
ISSN
2352-5401
DOI
10.2991/aer.k.210817.026How to use a DOI?
Copyright
© 2021, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Huang Hongliang
AU  - Tang Weiyu
AU  - Yang Juntao
AU  - Wang Lidong
PY  - 2021
DA  - 2021/08/18
TI  - Parameters Calibration of CT System Based On Geometric Model and Inverse Radon Transform
BT  - Proceedings of the 2021 10th International Conference on Applied Science, Engineering and Technology (ICASET 2021)
PB  - Atlantis Press
SP  - 113
EP  - 123
SN  - 2352-5401
UR  - https://doi.org/10.2991/aer.k.210817.026
DO  - 10.2991/aer.k.210817.026
ID  - Hongliang2021
ER  -