Proceedings of the 2017 6th International Conference on Measurement, Instrumentation and Automation (ICMIA 2017)

Experimental Research on geogrids Creep property of at different low temperatures

Authors
Lianzhong Yin
Corresponding Author
Lianzhong Yin
Available Online June 2017.
DOI
10.2991/icmia-17.2017.89How to use a DOI?
Keywords
geogrids, creep property, creep test
Abstract

Creep property is the key factor for effecting geogrid-reinforced earth retaining structures under a long-term behavior. Contrast test is adopted for creep property of geogrids under different temperature in the indoor test. The result indicates as follows: creep property of plastic geogrids is totally different with different temperature. So temperature has a great influence on creep property of geogrids. The lower the temperature is, the smaller the creep is.

Copyright
© 2017, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the 2017 6th International Conference on Measurement, Instrumentation and Automation (ICMIA 2017)
Series
Advances in Intelligent Systems Research
Publication Date
June 2017
ISBN
10.2991/icmia-17.2017.89
ISSN
1951-6851
DOI
10.2991/icmia-17.2017.89How to use a DOI?
Copyright
© 2017, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Lianzhong Yin
PY  - 2017/06
DA  - 2017/06
TI  - Experimental Research on geogrids Creep property of at different low temperatures
BT  - Proceedings of the 2017 6th International Conference on Measurement, Instrumentation and Automation (ICMIA 2017)
PB  - Atlantis Press
SP  - 516
EP  - 519
SN  - 1951-6851
UR  - https://doi.org/10.2991/icmia-17.2017.89
DO  - 10.2991/icmia-17.2017.89
ID  - Yin2017/06
ER  -