Proceedings of the6th International Conference on Mechatronics, Materials, Biotechnology and Environment (ICMMBE 2016)

Establishment of Inter-harmonic Flicker Curve for Fluorescent Lamp

Authors
Huiyan Cao, Tong Wu, Shuyi Tao, Jie Sun, Zhili Tian, Qiang Zhao, Jia Cui, Linze Gao
Corresponding Author
Huiyan Cao
Available Online September 2016.
DOI
10.2991/icmmbe-16.2016.83How to use a DOI?
Keywords
inter-harmonic; flicker; curve; experimental platform; fluorescent lamp
Abstract

In order to analyze the inter-harmonic affections on the voltage flicker, the relationship between the inter-harmonics and flicker analysis are carried out. In order to be able to accurately determine the level of inter-harmonics to make the electric light flicker, inter-harmonic-flicker limit curve drawing method based on the voltage flicker constraints is established. Analog tester flicker and inter-harmonic-flicker experimental platform are built; limit curve can be drawn through the experimental data. The 2 kinds of harmonic-flicker limit curves for the 220 V, 50 Hz fluorescent lamp are drawn by the 2 methods separately, and the analysis results show that the accuracy of the results obtained by the two methods, the level of inter-harmonics whether lead to fluorescent flicker can be determined by the curves. The methods have the small amount of calculation, and are practical and easy to implement.

Copyright
© 2016, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the6th International Conference on Mechatronics, Materials, Biotechnology and Environment (ICMMBE 2016)
Series
Advances in Engineering Research
Publication Date
September 2016
ISBN
10.2991/icmmbe-16.2016.83
ISSN
2352-5401
DOI
10.2991/icmmbe-16.2016.83How to use a DOI?
Copyright
© 2016, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Huiyan Cao
AU  - Tong Wu
AU  - Shuyi Tao
AU  - Jie Sun
AU  - Zhili Tian
AU  - Qiang Zhao
AU  - Jia Cui
AU  - Linze Gao
PY  - 2016/09
DA  - 2016/09
TI  - Establishment of Inter-harmonic Flicker Curve for Fluorescent Lamp
BT  - Proceedings of the6th International Conference on Mechatronics, Materials, Biotechnology and Environment (ICMMBE 2016)
PB  - Atlantis Press
SP  - 445
EP  - 450
SN  - 2352-5401
UR  - https://doi.org/10.2991/icmmbe-16.2016.83
DO  - 10.2991/icmmbe-16.2016.83
ID  - Cao2016/09
ER  -