Design and Realization of Calibration Device for Angular Positioning Error of Universal Turntable
Authors
Huahui Yang, Fu Liu, Jun Zhou, Weili Feng
Corresponding Author
Huahui Yang
Available Online December 2015.
- DOI
- 10.2991/icmmcce-15.2015.448How to use a DOI?
- Keywords
- angular positioning error, horizontal capacitance sensor, mental circular grating, angle contact bearing.
- Abstract
In order to realize the calibration measurement of universal turntable in high precision, a calibration device is designed and realized. The device was mainly composed of horizontal capacitance sensor, mental circular grating, ultrasonic motor, and double-row angular contact bearings was selected as its slewing mechanism, so rotation precision of calibration instrument can be improved. Finally, this paper put the error testing results of calibration instrument each system, which satisfy the demand for calibration measurement and provide references for carrying out uncertainty analysis.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Huahui Yang AU - Fu Liu AU - Jun Zhou AU - Weili Feng PY - 2015/12 DA - 2015/12 TI - Design and Realization of Calibration Device for Angular Positioning Error of Universal Turntable BT - Proceedings of the 4th International Conference on Mechatronics, Materials, Chemistry and Computer Engineering 2015 PB - Atlantis Press SP - 1119 EP - 1126 SN - 2352-538X UR - https://doi.org/10.2991/icmmcce-15.2015.448 DO - 10.2991/icmmcce-15.2015.448 ID - Yang2015/12 ER -