Proceedings of the First International Conference on Progressive Civil Society (ICONPROCS 2019)

The Simulations of Energy based on the Building Masterplan of RSUD Pandan Arang Boyolali

Authors
Isra' Darmawan, Basuki Basuki, Priyono Yulianto, Susatyo Pramono, Novi SP, Iwan Rustendi
Corresponding Author
Isra' Darmawan
Available Online May 2019.
DOI
10.2991/iconprocs-19.2019.63How to use a DOI?
Keywords
DesignBuilder, Energyplus, Efficiency energy, System constant air volume, System variable air volume
Abstract

Safe and comfortable are important factors which can affect to the patient's healing process. However, the patient room designed up to standard requires to creating healthy, safety, and comfortable for inpatient room. This study aims to simulate energy consumption based on Masterplan of the local government hospital of Pandan Arang Boyolali (Rumah Sakit Umum Daerah, RSUD Pandan Arang Boyolali) that prediction the energy saving scenario from a simulation using DesignBuilder software. Definitely, the data’s required including the geometry data, weather data, and the cooling load data. Henceforth, the building geometry data is from the blueprint result is then modeled into a 3-dimensional model using the DesignBuilder software and the EnergyPlus analyzed. Whereas the weather data is used based on the Surakarta region data, absolutely this is due to the unavailability of the weather data for the Boyolali region. Furthermore, the cooling load data is covered by the occupant sector, and the lighting system sector. The simulation results show that the electrical energy consumption of the whole building is 5,921.77 kWh for about 1 year and the use of the air system energy is about 568,369.75 kWh or equal to 92% of the total energy use, and about 51,936.53 kWh or about equal to 8% of the lighting system. Meanwhile, the energy saving scenario replace the Variable Air Volume (VAV) air system into Constant Air Volume (CAV). The role of the CAV system to energy savings is evidenced by comparison with the VAV system. Thereby, through of this comparison result has obtained about 0.475% of savings value by the CAV system with the nominal price of Rp. 5.477.637.25, -. However, the value of Energy Consumption intensity (IKE) is 126.56 kWh/m2/year, which is still below to standard of the issued by GBCI. Therefore, it can be categorized as a green building

Copyright
© 2019, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the First International Conference on Progressive Civil Society (ICONPROCS 2019)
Series
Advances in Social Science, Education and Humanities Research
Publication Date
May 2019
ISBN
10.2991/iconprocs-19.2019.63
ISSN
2352-5398
DOI
10.2991/iconprocs-19.2019.63How to use a DOI?
Copyright
© 2019, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Isra' Darmawan
AU  - Basuki Basuki
AU  - Priyono Yulianto
AU  - Susatyo Pramono
AU  - Novi SP
AU  - Iwan Rustendi
PY  - 2019/05
DA  - 2019/05
TI  - The Simulations of Energy based on the Building Masterplan of RSUD Pandan Arang Boyolali
BT  - Proceedings of the First International Conference on Progressive Civil Society (ICONPROCS 2019)
PB  - Atlantis Press
SP  - 297
EP  - 301
SN  - 2352-5398
UR  - https://doi.org/10.2991/iconprocs-19.2019.63
DO  - 10.2991/iconprocs-19.2019.63
ID  - Darmawan2019/05
ER  -