Study on temperature drop of molten steel during converter tapping
- DOI
- 10.2991/icseee-15.2016.90How to use a DOI?
- Keywords
- converter; tapping; molten steel temperature; mathematical model
- Abstract
Molten steel temperature in ladle after converter tapping has a strong effect on yield rate of alloy, dosage of deoxidizing agent and production efficiency. A mathematical model taking ladle thermal state into account was established for temperature prediction of molten steel during tapping and it was compared with the measured values. The results obtained show that the heat loss from molten steel stream to ambient is almost negligible due to less distance from tapping hole to ladle hole, and the total percentage of heat losses from ladle lining and top surface of steel bath is above 60%. The higher tapping temperature is, and the greater decalescence of ladle lining is,the greater temperature drop is. When tapping quantity is reduced by 20ton, molten steel temperature after tapping is reduced by about 6℃ additionally.
- Copyright
- © 2016, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Zhiyong Fan AU - Wei Xiong AU - Yifei Huang PY - 2016/04 DA - 2016/04 TI - Study on temperature drop of molten steel during converter tapping BT - Proceedings of the 2015 4th International Conference on Sustainable Energy and Environmental Engineering PB - Atlantis Press SP - 538 EP - 542 SN - 2352-5401 UR - https://doi.org/10.2991/icseee-15.2016.90 DO - 10.2991/icseee-15.2016.90 ID - Fan2016/04 ER -