The Research on Heat Treatment Technology of Ni - Mo - P Electroless Plating
- DOI
- 10.2991/mcei-16.2016.254How to use a DOI?
- Keywords
- Heat treatment; Ni-Mo-P electroless plating; Hardness; Uniform design
- Abstract
In this paper, study on the Ni-Mo-P electroless plating which are heat treated with different time and temperature. Test and record the hardness of coatings by the micro-hardness tester. Modeling analysis and optimize the parameters of the coating hardness by uniform design methods. The results indicate that under the same experiment parameters, the maximum hardness of the Ni-Mo-P electroless plating are mainly effect by the heating time and temperature. The hardness decrease when the heat temperature is over high and heating over long time. Got the hardest coating after the heat treatment technology of 380 ~ 400 for 3 h.
- Copyright
- © 2017, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Jinkui Cao AU - Huahui Yi AU - Zhengcheng Zhang PY - 2016/12 DA - 2016/12 TI - The Research on Heat Treatment Technology of Ni - Mo - P Electroless Plating BT - Proceedings of the 2016 6th International Conference on Mechatronics, Computer and Education Informationization (MCEI 2016) PB - Atlantis Press SP - 1240 EP - 1244 SN - 1951-6851 UR - https://doi.org/10.2991/mcei-16.2016.254 DO - 10.2991/mcei-16.2016.254 ID - Cao2016/12 ER -