Proceedings of the 2016 6th International Conference on Machinery, Materials, Environment, Biotechnology and Computer

The design of detecting Aflatoxins based on continuous wave light source

Authors
Xuyang Zhao, Hao Yang, Guojin Shen, Yingjie Ding
Corresponding Author
Xuyang Zhao
Available Online June 2016.
DOI
10.2991/mmebc-16.2016.202How to use a DOI?
Keywords
closed loop feedback; stable light source; fixed wavelength; high frequency; Single Photon Counting
Abstract

the separation of elements is achieved by ultra performance liquid chromatography system for Aflatoxins, the use of a closed-loop feedback control system is to produce a stable continuous wave light source, fixed wavelength of 360nm illumination light source onto the separation of elements, resulting in the emission wavelength was 440nm receiving photomultiplier tube, and then it gets high-frequency pulses. By single photon counting system pulse will be integrated for a fixed time , aflatoxin can be obtained G1, B1, G2, B2 content elements through the peak area calculation. Without derivatives quantitative determination of aflatoxin can be carried out quickly and efficiently. This design can effectively address the impact of the stability of the light source on the test results. It is useful for analysis LED spectral characteristics.

Copyright
© 2016, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the 2016 6th International Conference on Machinery, Materials, Environment, Biotechnology and Computer
Series
Advances in Engineering Research
Publication Date
June 2016
ISBN
10.2991/mmebc-16.2016.202
ISSN
2352-5401
DOI
10.2991/mmebc-16.2016.202How to use a DOI?
Copyright
© 2016, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Xuyang Zhao
AU  - Hao Yang
AU  - Guojin Shen
AU  - Yingjie Ding
PY  - 2016/06
DA  - 2016/06
TI  - The design of detecting Aflatoxins based on continuous wave light source
BT  - Proceedings of the 2016 6th International Conference on Machinery, Materials, Environment, Biotechnology and Computer
PB  - Atlantis Press
SP  - 972
EP  - 975
SN  - 2352-5401
UR  - https://doi.org/10.2991/mmebc-16.2016.202
DO  - 10.2991/mmebc-16.2016.202
ID  - Zhao2016/06
ER  -