Proceedings of the 2013 the International Conference on Remote Sensing, Environment and Transportation Engineering (RSETE 2013)

Application analysis of the recovery fresh air heat pump units in the public building in the cold and serious cold regions

Authors
Aoxue Chen, Chunyu Ran, Hailong Liu
Corresponding Author
Aoxue Chen
Available Online August 2013.
DOI
10.2991/rsete.2013.12How to use a DOI?
Keywords
the cold and serious cold regions, the recovery fresh air heat pump units, anti freezing, heat recovery efficiency, COP
Abstract

This article analysis the running conditions and existing problems of air conditioning system for existing public buildings in the cold and serious cold regions in winter,and compares analysis of the solution of the anti freezing measures for the fresh air unit,introduces the recovery exhaust energy by the means of heat exchange to resolve the existing problems of air conditioning system in winter.The results show that the outdoor temperature changes from -25~10ºC degree, the degree of air supply can reach more than 10 degree ,which means that system which recovers the exhaust energy can preheat the fresh air more than 10 degree.The COP of recovery fresh air heat pump units reaches more than 3.8, and the heat recovery efficiency up to 82%.It can prolong the heat pump units and the fresh air units run in the period of heating, guarantee well IAQ for a long time.

Copyright
© 2013, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the 2013 the International Conference on Remote Sensing, Environment and Transportation Engineering (RSETE 2013)
Series
Advances in Intelligent Systems Research
Publication Date
August 2013
ISBN
10.2991/rsete.2013.12
ISSN
1951-6851
DOI
10.2991/rsete.2013.12How to use a DOI?
Copyright
© 2013, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Aoxue Chen
AU  - Chunyu Ran
AU  - Hailong Liu
PY  - 2013/08
DA  - 2013/08
TI  - Application analysis of the recovery fresh air heat pump units in the public building in the cold and serious cold regions
BT  - Proceedings of the 2013 the International Conference on Remote Sensing, Environment and Transportation Engineering (RSETE 2013)
PB  - Atlantis Press
SP  - 46
EP  - 49
SN  - 1951-6851
UR  - https://doi.org/10.2991/rsete.2013.12
DO  - 10.2991/rsete.2013.12
ID  - Chen2013/08
ER  -