Proceedings of the International Conference on Health and Medical Sciences (AHMS 2020)

Clarity of Anatomic Information: Comparison of Variations in Combination of Time Repetition (TR) and Echo Train Length (ETL) MRI Lumbar Sequence T2W Turbo Spin Echo in the Diagnosis of Low Back Pain

Authors
Rini Indrati, Lies Mardiyana, Ainul Amarudin, Emi Murniati, Siti Daryati, Sri Mulyati, Dwi Rochmayanti
Corresponding Author
Rini Indrati
Available Online 27 January 2021.
DOI
10.2991/ahsr.k.210127.003How to use a DOI?
Keywords
MRI Lumbar sagittal, T2W TSE, variation of TR and ETL
Abstract

Time Repetition (TR) and Echo Train Length (ETL) are the parameters in MRI that can be adjusted by a radiographer to affect image quality, anatomic information, and scan time. There are various TR and ETL adjustments used for lumbar MR imaging. This study is to determine the differences in the combination of TR and ETL to the anatomic information of the images. This is an experimental research. Data were collected from 30 patients with variations of TR1000, TR2000, ETL13, ETL17, and ETL21. The Images were evaluated by radiologists. Evaluation of the images were conducted on the corpus vertebrae, inter vertebral disc, conus medullar, cerebrospinal fluid and ligamentum flavum. The data were analyzed using Friedman test with 95% CI. The results show that the combination of TR and ETL variations affect the anatomic information of T2WI TSE sagittal lumbar MRI. The Friedman test shows differences of image anatomic information from variations of the combination of TR and ETL (p-value = 0.001). The Combination of TR2000 ETL17 produces optimal image information.

Copyright
© 2021, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the International Conference on Health and Medical Sciences (AHMS 2020)
Series
Advances in Health Sciences Research
Publication Date
27 January 2021
ISBN
978-94-6239-322-6
ISSN
2468-5739
DOI
10.2991/ahsr.k.210127.003How to use a DOI?
Copyright
© 2021, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Rini Indrati
AU  - Lies Mardiyana
AU  - Ainul Amarudin
AU  - Emi Murniati
AU  - Siti Daryati
AU  - Sri Mulyati
AU  - Dwi Rochmayanti
PY  - 2021
DA  - 2021/01/27
TI  - Clarity of Anatomic Information: Comparison of Variations in Combination of Time Repetition (TR) and Echo Train Length (ETL) MRI Lumbar Sequence T2W Turbo Spin Echo in the Diagnosis of Low Back Pain
BT  - Proceedings of the International Conference on Health and Medical Sciences (AHMS 2020)
PB  - Atlantis Press
SP  - 10
EP  - 14
SN  - 2468-5739
UR  - https://doi.org/10.2991/ahsr.k.210127.003
DO  - 10.2991/ahsr.k.210127.003
ID  - Indrati2021
ER  -