Dynamic response of the axial flow pump induced by the fluid excitation
- DOI
- 10.2991/asei-15.2015.71How to use a DOI?
- Keywords
- axial flow pump; vibration; model dynamics; fluid excitation; responses
- Abstract
The dynamic response for the axial flow pump induced by the fluid excitation is analyzed in this paper. The responses of the axial flow pump during the operation were mostly generated by the fluid excitation and motor excitation. The finite element model was accomplished in this article with consideration of the effect of the fluid excitation and the motor excitation forces. Based on the modal dynamics method, the analysis is carried out to study on the coupling responses under the two excitations. The results show that the vibration source includes the impeller frequency, the axial frequency and the frequency-doubled of the impeller; the response of the motor excitation occupies a leading position in the spectrogram. The research work is meaningful for solving the response induced by the flow excitation of the axial flow pumps.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Guofang Nan AU - Yuanlu Zhang AU - Eryun Chen PY - 2015/05 DA - 2015/05 TI - Dynamic response of the axial flow pump induced by the fluid excitation BT - Proceedings of the 2015 International conference on Applied Science and Engineering Innovation PB - Atlantis Press SP - 330 EP - 334 SN - 2352-5401 UR - https://doi.org/10.2991/asei-15.2015.71 DO - 10.2991/asei-15.2015.71 ID - Nan2015/05 ER -