Proceedings of the 2nd International Conference on Civil, Materials and Environmental Sciences

In-Situ Monitoring of the Effect of External Environment on a Contemporary Building in Prague: The Performance of the Additional Thermal Insulation System

Authors
Zbyšek Pavlík, Jan Fort, Pavel Beran, Robert Erný
Corresponding Author
Zbyšek Pavlík
Available Online April 2015.
DOI
10.2991/cmes-15.2015.8How to use a DOI?
Keywords
external environment, in situ monitoring, contact thermal insulation system, polystyrene board, hygrothermal function
Abstract

Experimental assessment of the hygrothermal performance of an office building in Prague, which was recently provided by an additional contact thermal insulation system (TIS), is done in the paper, in order to evaluate the contribution of the applied TIS to the moderation of the interior climate. At the long-term in-situ analysis of the building, the measurement of relative humidity and temperature profiles along the cross section of a selected part of the building envelope is carried out. The measurement is realised for 1.5 year on the non-insulated wall at first, and after the application of the exterior TIS it continues for another 1 year. The obtained results show an improvement in the hygrothermal function of the analysed building envelope due to the application of TIS that reduces significantly the thermal response of the investigated building to the changes of environmental conditions.

Copyright
© 2015, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the 2nd International Conference on Civil, Materials and Environmental Sciences
Series
Advances in Engineering Research
Publication Date
April 2015
ISBN
10.2991/cmes-15.2015.8
ISSN
2352-5401
DOI
10.2991/cmes-15.2015.8How to use a DOI?
Copyright
© 2015, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Zbyšek Pavlík
AU  - Jan Fort
AU  - Pavel Beran
AU  - Robert Erný
PY  - 2015/04
DA  - 2015/04
TI  - In-Situ Monitoring of the Effect of External Environment on a Contemporary Building in Prague: The Performance of the Additional Thermal Insulation System
BT  - Proceedings of the 2nd International Conference on Civil, Materials and Environmental Sciences
PB  - Atlantis Press
SP  - 28
EP  - 30
SN  - 2352-5401
UR  - https://doi.org/10.2991/cmes-15.2015.8
DO  - 10.2991/cmes-15.2015.8
ID  - Pavlík2015/04
ER  -