Proceedings of the 2015 6th International Conference on Manufacturing Science and Engineering

Present situation of research and Application of High Intensity Focusing Ultrasonic Therapy

Authors
Li Liu, Song Zhang
Corresponding Author
Li Liu
Available Online December 2015.
DOI
10.2991/icmse-15.2015.91How to use a DOI?
Keywords
High intensity focusing ultrasonic, Transducer, Non-invasive temperature measurement
Abstract

High intensity focused ultrasound (HIFU) is the fourth brand-new and efficient means to cure tumour acknowledged by the medical field. China is regarded as one of countries applying HIFU to clinical oncotherapy earliest in the world. However, a considerable part of HIFU equipments which have been put on the market leave unused because accidental injuries such as ambustion to the body surface, tumour tissue residues in the target section or damages to normal tissues are often caused in HIFU clinical treatment. In the paper, ultrasonic focusing method, temperature measurement technique of high-intensity focusing ultrasonic therapy is introduced; studies of current situations of cell and multiplex array focusing transducers and their existing problems are focally analyzed and illustrated based on analyzing challenges faced by HIFU treatment at present. This study suggested that phased array was theoretically easy for realizing accurate control of computer however, unbeneficial factors and engineering technical problems still exist.

Copyright
© 2015, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the 2015 6th International Conference on Manufacturing Science and Engineering
Series
Advances in Engineering Research
Publication Date
December 2015
ISBN
10.2991/icmse-15.2015.91
ISSN
2352-5401
DOI
10.2991/icmse-15.2015.91How to use a DOI?
Copyright
© 2015, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Li Liu
AU  - Song Zhang
PY  - 2015/12
DA  - 2015/12
TI  - Present situation of research and Application of High Intensity Focusing Ultrasonic Therapy
BT  - Proceedings of the 2015 6th International Conference on Manufacturing Science and Engineering
PB  - Atlantis Press
SP  - 506
EP  - 509
SN  - 2352-5401
UR  - https://doi.org/10.2991/icmse-15.2015.91
DO  - 10.2991/icmse-15.2015.91
ID  - Liu2015/12