Classifying low formaldehyde emission from blockboard by gas analysis method and desiccator method
- DOI
- 10.2991/ifeesm-15.2015.94How to use a DOI?
- Keywords
- Blockboard; formaldehyde emission; desiccator method; gas analysis method; moisture content
- Abstract
The paper studied formaldehyde emission (FE) of E0 class blockboards by desiccator and gas analysis method. Results showed that for the same formaldehyde emission value got from desiccator method, the gas analysis (GA) values were quite different. It was suggested to use gas analysis method to evaluate formaldehyde emission at low formaldehyde content. The main reason for different gas analysis values was moisture content (MC), the lower the board moisture content the smaller the formaldehyde emission value. Gas analysis value was very sensitive to specimen’s moisture content, it was suggested to keep low moisture content could be a solution to decrease formaldehyde emission for blockboards.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Haixia Yu AU - Xuan Ma AU - Liu Yang AU - Chongrong Fang AU - Manping Xu PY - 2015/09 DA - 2015/09 TI - Classifying low formaldehyde emission from blockboard by gas analysis method and desiccator method BT - Proceedings of the 2015 International Forum on Energy, Environment Science and Materials PB - Atlantis Press SP - 496 EP - 501 SN - 2352-5401 UR - https://doi.org/10.2991/ifeesm-15.2015.94 DO - 10.2991/ifeesm-15.2015.94 ID - Yu2015/09 ER -