Proceedings of the 2015 International Conference on Mechatronics, Electronic, Industrial and Control Engineering

Digital Control Method of Volume Clamp Method

Authors
Shouping Wang, Jia Liu, Pandeng Zhang, Xiaodan Yang, Lu Huang
Corresponding Author
Shouping Wang
Available Online April 2015.
DOI
10.2991/meic-15.2015.157How to use a DOI?
Keywords
volume clamp method; blood volume pulse; anti-interference; real-time performance;frequency measurement
Abstract

The volume clamp method is a kind of non-invasive continuous blood pressure measurement methods, the traditional method is to convert light into a weak current to collect the signal of blood volume pulse by a sensor. In the process of signal transmission, it can be easily disturbed. We adopt a new method, the light is converted into frequency signal, by adopting a suitable method of frequency measurement, we can obtain blood volume pulse. This method improves anti-interference in the process of signal transmission, removes amplifier circuit and filter circuit. Meanwhile, this method also improves the measurement accuracy and real-time of system. On the other hand, due to removing AD, we reduce the cost of system. At the end of this paper, we set up a hardware platform to respectively acquire blood volume pulse with the traditional method and our new method, the results show: the blood volume pulse with our new method is better than that with traditional method.

Copyright
© 2015, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the 2015 International Conference on Mechatronics, Electronic, Industrial and Control Engineering
Series
Advances in Engineering Research
Publication Date
April 2015
ISBN
10.2991/meic-15.2015.157
ISSN
2352-5401
DOI
10.2991/meic-15.2015.157How to use a DOI?
Copyright
© 2015, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Shouping Wang
AU  - Jia Liu
AU  - Pandeng Zhang
AU  - Xiaodan Yang
AU  - Lu Huang
PY  - 2015/04
DA  - 2015/04
TI  - Digital Control Method of Volume Clamp Method
BT  - Proceedings of the 2015 International Conference on Mechatronics, Electronic, Industrial and Control Engineering
PB  - Atlantis Press
SP  - 691
EP  - 694
SN  - 2352-5401
UR  - https://doi.org/10.2991/meic-15.2015.157
DO  - 10.2991/meic-15.2015.157
ID  - Wang2015/04
ER  -