Artery Research

Volume 25, Issue Supplement 1, December 2019, Pages S41 - S41

5.5 A Femoral ‘Stealing’ Effect: Presence of Collateral Retrograde Blood Flow Redistribution in the Femoral Bifurcation During Reactive Hyperemia

Authors
Jason Au1, 2, *, Robert Amelard2, Billy Yiu1, 2, Hassan Nahas1, 2, Richard Hughson2, Alfred Yu1, 2
1University of Waterloo, Waterloo, Canada
2Schlegel-University of Waterloo Research Institute for Aging, Waterloo, Canada
*Corresponding author. Email: jason.au@uwaterloo.ca
Corresponding Author
Jason Au
Available Online 15 February 2020.
DOI
10.2991/artres.k.191224.034How to use a DOI?
Abstract

Background & Purpose: The femoral bifurcation houses complex flow recirculation that may be impacted by downstream peripheral resistance; however, conventional ultrasound is unable to quantify multi-directional flow to study these phenomena. The purpose of this study was to examine the multi-directional behavior of blood in the femoral bifurcation during reactive hyperemia (RH) using vector flow imaging.

Methods: Nine healthy adults (25 ± 4 years; 5 men) underwent high-frame-rate ultrasound imaging of their right femoral bifurcation at rest, and during the first cardiac cycle of RH after 5-min of 200 mmHg calf occlusion. Multi-angle Doppler ultrasound was used to qualitatively describe vector blood flow at 750 fps [1]. The bifurcation region was isolated for blood vector dispersion analysis, an index of flow directionality [2].

Results: Blood flow during RH was characterized by near-constant anterograde blood flow to the superficial femoral artery (SFA), adjacent to low/oscillatory flow immediately proximal to the deep femoral artery (DFA) (Figure 1). We observed collateral blood flow redistribution in 3/9 participants, where blood from the DFA appeared to re-enter the SFA during the retrograde flow period. Bifurcation vector dispersion was reduced from baseline (0.53 ± 0.08 vs 0.67 ± 0.09; p < 0.01), but not eliminated, due to preservation of DFA flow reversal.

Conclusion: We demonstrate the presence of distinct, and potentially interacting, blood flow streams within the femoral bifurcation during RH. These observations were made possible by the emerging vector flow imaging technique to study complex hemodynamics in vivo, and suggest novel mechanisms by which blood is distributed to vascular beds, in extreme flow profiles.

Figure 1

Left: Representative example (31 yr old man) of vector projectile imaging of the femoral bifurcation at end-systole; vectors within the red region of interest were extracted to calculate vector dispersion. Right: Representative example of blood vector dispersion at rest and during hyperemia during a single cardiac cycle; values closer to 0 indicate greater dispersion.

Copyright
© 2019 Association for Research into Arterial Structure and Physiology. Publishing services by Atlantis Press International B.V.
Open Access
This is an open access article distributed under the CC BY-NC 4.0 license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)
View full text (HTML)

Journal
Artery Research
Volume-Issue
25 - Supplement 1
Pages
S41 - S41
Publication Date
2020/02/15
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.2991/artres.k.191224.034How to use a DOI?
Copyright
© 2019 Association for Research into Arterial Structure and Physiology. Publishing services by Atlantis Press International B.V.
Open Access
This is an open access article distributed under the CC BY-NC 4.0 license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - JOUR
AU  - Jason Au
AU  - Robert Amelard
AU  - Billy Yiu
AU  - Hassan Nahas
AU  - Richard Hughson
AU  - Alfred Yu
PY  - 2020
DA  - 2020/02/15
TI  - 5.5 A Femoral ‘Stealing’ Effect: Presence of Collateral Retrograde Blood Flow Redistribution in the Femoral Bifurcation During Reactive Hyperemia
JO  - Artery Research
SP  - S41
EP  - S41
VL  - 25
IS  - Supplement 1
SN  - 1876-4401
UR  - https://doi.org/10.2991/artres.k.191224.034
DO  - 10.2991/artres.k.191224.034
ID  - Au2020
ER  -