Proceedings of the 2014 International Conference on Physics and its Applications

Study of EHD Flow Produced by Pin-Dual Ring Concentric Electrodes Generator

Authors
Sumariyah Sumariyah, Zaenul Muhlisin, Evi Setiawati
Corresponding Author
Sumariyah Sumariyah
Available Online September 2014.
DOI
10.2991/icopia-14.2015.31How to use a DOI?
Keywords
EHD Flow, Discharge corona,pin-dual ring concentric electrodes, EHD Flow velocity.
Abstract

The aim of this research is study of Electrohydrodynamic (EHD) flow by discharge corona generator with electrodes configuration of Pin- Dual Ring Concentric. We measured the velocity of EHD flow with electrodes configuration of Pin- Dual Ring Concentric and compare the result to Pin-Single Ring electrodes. The pin needle was made by stainless steel with a length of 50 mm and a tip diameter of 0.01 mm. The dual ring electrodes constructed by two metal material connected to each other with diameter of 24 mm and width of 16 mm. The thickness of rings is 2 mm and 3 mm, respectively. Single ring electrode has diameter, width and thickness of 24 mm , 2 mm and 3 mm, respectively. The EHD was generated by using a DC high voltage of 10 kV. The Pin act as an active electrode of corona discharge and concentric rings dual / single ring electrodes act as ions collector and passive electrodes. The velocity of EHD flow was measured by a Hot - Wire Anemometer. We found that the velocity of EHD flow with electrodes configuration of pin-dual ring concentric electrodes is larger than pin-single ring electrode. The velocity of EHD flow for two cases of electrodes configuration were saturated at the certain spacing of inter-electrodes distance. The maximum velocity of the of EHD flow using electrodes configuration of pin-dual rings concentric was 0,6 m/s at a distance of inter-electrodes distance 6 mm and a voltage of 3,2 kV.

Copyright
© 2015, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the 2014 International Conference on Physics and its Applications
Series
Advances in Physics Research
Publication Date
September 2014
ISBN
10.2991/icopia-14.2015.31
ISSN
2352-541X
DOI
10.2991/icopia-14.2015.31How to use a DOI?
Copyright
© 2015, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Sumariyah Sumariyah
AU  - Zaenul Muhlisin
AU  - Evi Setiawati
PY  - 2014/09
DA  - 2014/09
TI  - Study of EHD Flow Produced by Pin-Dual Ring Concentric Electrodes Generator
BT  - Proceedings of the 2014 International Conference on Physics and its Applications
PB  - Atlantis Press
SP  - 157
EP  - 160
SN  - 2352-541X
UR  - https://doi.org/10.2991/icopia-14.2015.31
DO  - 10.2991/icopia-14.2015.31
ID  - Sumariyah2014/09
ER  -