Proceedings of the 2019 2nd International Conference on Sustainable Energy, Environment and Information Engineering (SEEIE 2019)

Rapping Strategy and Electric Field Characteristics of ESP in a Power Plant

Authors
Guoliang Li, Xiao Jia, Jie Ren, Binbin Sun, Xue Wang
Corresponding Author
Xue Wang
Available Online May 2019.
DOI
10.2991/seeie-19.2019.47How to use a DOI?
Keywords
rapping parameters; secondary voltage and current; ESP; energy consumption component
Abstract

The electric field operating and rapping parameters of 1# Electrostatic Precipitators (ESP) had been monitored and analysed in a thermal power company. There were five electric fields in the ESP. The rapping time of 1# ESP was 150 seconds. The time interval when the rapping was stopped increased sequentially from the first to the fifth electrical field, and the neighbouring two electric fields did not overlap each other. The operating voltage in 1# ESP also went up sequentially from the first to the fifth electrical field. The secondary voltage and current of each electric field was closely related to the rapping interval. The total energy consumption was suggested to be 26.6-29 kW to keep the dust emission under 20 mg/Nm3.

Copyright
© 2019, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the 2019 2nd International Conference on Sustainable Energy, Environment and Information Engineering (SEEIE 2019)
Series
Advances in Engineering Research
Publication Date
May 2019
ISBN
10.2991/seeie-19.2019.47
ISSN
2352-5401
DOI
10.2991/seeie-19.2019.47How to use a DOI?
Copyright
© 2019, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Guoliang Li
AU  - Xiao Jia
AU  - Jie Ren
AU  - Binbin Sun
AU  - Xue Wang
PY  - 2019/05
DA  - 2019/05
TI  - Rapping Strategy and Electric Field Characteristics of ESP in a Power Plant
BT  - Proceedings of the 2019 2nd International Conference on Sustainable Energy, Environment and Information Engineering (SEEIE 2019)
PB  - Atlantis Press
SP  - 205
EP  - 208
SN  - 2352-5401
UR  - https://doi.org/10.2991/seeie-19.2019.47
DO  - 10.2991/seeie-19.2019.47
ID  - Li2019/05
ER  -